Leak Prevention & Detection of MV Gas-Insulated RMU Switchgear

2026-10-12 For SF6-insulated Ring Main Units (RMU) or GIS, the leakage rate requirement depends on whether the gas compartment is classified as a closed pressure system or a sealed pressure system under IEC standards. 1. IEC 62271-1 (General HV Switchgear Standard) IEC 62271-1 defines: Gas system type Maximum SF6 leakage rate Closed pressure system ≤ 0.5% per year […]

Leak Prevention & Detection of MV Gas-Insulated RMU Switchgear Baca selengkapnya "

Why Do Some Switchgear Have One CT While Others Have Three?

2026-10-12 Current transformers are widely used in power systems; their function is to induce a small current—proportional to the current flowing through a high-current cable—for use in metering and relay protection. What is the function of a current transformer? To ensure the safe and economical operation of a power system, it is essential to monitor

Why Do Some Switchgear Have One CT While Others Have Three? Baca selengkapnya "

The Function Composition &Basic Structure Of The Operating Mechanism of MV Circuit Breakers

2026-06-10 I.Medium-voltage circuit breakers mainly consist of the circuit breaker body and the operating mechanism. With continuous technological updates to circuit breakers, the possibility of failure in the circuit breaker body is decreasing, and circuit breaker failures are concentrated in the operating mechanism. According to statistics on medium-voltage circuit breaker operation failures, among various circuit

The Function Composition &Basic Structure Of The Operating Mechanism of MV Circuit Breakers Baca selengkapnya "

Why Do RMU Frequently Burn Out Their Opening and Closing Coils?

2026-06-10 The “opening and closing coil” of a high-voltage circuit breaker is an important component of the circuit breaker’s electric operating mechanism. It is a hollow cylindrical coil wound with copper wire, possessing excellent conductivity. When current passes through the coil, it generates a magnetic field, which, through electromagnetic force, drives the positioning pins of

Why Do RMU Frequently Burn Out Their Opening and Closing Coils? Baca selengkapnya "

Necessity of Short-Circuit Making Capability for Earthing Switches in MV RMUs

2026-01-05 Functional Role of the Earthing Switch In medium-voltage ring main units (RMUs), the earthing switch (ES) is often regarded as a device intended solely for maintenance grounding. However, under several credible operating and fault conditions, the earthing switch may be required to make onto a live circuit and withstand the resulting short-circuit current. For

Necessity of Short-Circuit Making Capability for Earthing Switches in MV RMUs Baca selengkapnya "

Uji Rutin Mikro-Air SF6 GIS RMU

2025-04-15 According to the newly revised “Preventive Test Procedures for Power Equipment”, the moisture content of SF6 switches for newly commissioned and overhauled arc extinguishing compartments shall not exceed 150ppm, and shall not exceed 300ppm during operation. As for the harm of micro-water, the reason is obvious and will not be explained here. We mainly

Uji Rutin Mikro-Air SF6 GIS RMU Baca selengkapnya "

Introduction to the Parallel Arc Extinguishing Scheme of SF6-free Vacuum Load Break Switches in MV Ring Main Unit

2024-12-12 Ketika rangkaian tegangan tinggi terputus, tegangan akan memecah udara untuk menghasilkan gas bebas suhu tinggi dan konduktivitas tinggi, yang muncul sebagai percikan suhu tinggi seketika, yang merupakan busur. Kerusakan busur sangat tinggi: busur akan menghasilkan suhu tinggi, yang akan mengikis permukaan kontak dan membakar

Introduction to the Parallel Arc Extinguishing Scheme of SF6-free Vacuum Load Break Switches in MV Ring Main Unit Baca selengkapnya "

“Hubungan Dua Arah” Antara ABB dan Xiamen Telah Mendorong Perkembangan Pesat Klaster Industri Tegangan Menengah Xiamen!

2024-12-12 Xiamen, Tiongkok, menjadi tujuan Ma Teng, presiden global bisnis kelistrikan Grup ABB, sebagai “perjalanan bisnis pertamanya” di tahun baru. Pada 9 Januari 2024, para eksekutif perusahaan Fortune 500 ini melakukan perjalanan khusus ke Xiamen dari Belanda dan mengumumkan bahwa “dalam tiga tahun ke depan, mereka akan lebih jauh

“Hubungan Dua Arah” Antara ABB dan Xiamen Telah Mendorong Perkembangan Pesat Klaster Industri Tegangan Menengah Xiamen! Baca selengkapnya "

Schneider Electric Bangun Basis Produksi Tegangan Menengah Terbesar di Dunia di Xiamen

2014-12-12 Perusahaan multinasional Schneider Electric telah meningkatkan kehadirannya di Xiamen Torch High-tech Zone. Pada tanggal 26 April 2024, proyek Xiamen Torch Electric Power Industrial Park (Fase I) secara resmi memulai konstruksi. Setelah proyek selesai, proyek ini akan berfungsi sebagai Schneider Electric (Xiamen) Industrial Park, menciptakan basis produksi tegangan menengah terbesarnya di

Schneider Electric Bangun Basis Produksi Tegangan Menengah Terbesar di Dunia di Xiamen Baca selengkapnya "

Berakar di Xiamen Selama 25 Tahun Hitachi Energy Akan Berinvestasi dalam Membangun Lini Produksi Baru di Pangkalan Manufaktur Xiamen

2024-12-12 Pada tanggal 14 November 2024, Hitachi Energy berhasil menyelenggarakan perayaan ulang tahun ke-25 pangkalan manufaktur sakelar tegangan tinggi di Xiamen. Sebanyak sekitar 120 orang dalam industri dari dalam dan luar negeri diundang untuk menghadiri acara di tempat untuk menyaksikan pencapaian luar biasa Xiamen Hitachi Energy High Voltage Switch Co., Ltd. selama bertahun-tahun.

Berakar di Xiamen Selama 25 Tahun Hitachi Energy Akan Berinvestasi dalam Membangun Lini Produksi Baru di Pangkalan Manufaktur Xiamen Baca selengkapnya "