Leak Prevention & Detection of MV Gas-Insulated RMU Switchgear

2026-10-12 For SF6-insulated Ring Main Units (RMU) or GIS, the leakage rate requirement depends on whether the gas compartment is classified as a closed pressure system or a sealed pressure system under IEC standards. 1. IEC 62271-1 (General HV Switchgear Standard) IEC 62271-1 defines: Gas system type Maximum SF6 leakage rate Closed pressure system ≤ 0.5% per year […]

Leak Prevention & Detection of MV Gas-Insulated RMU Switchgear Đọc thêm »

Why Do Some Switchgear Have One CT While Others Have Three?

2026-10-12 Current transformers are widely used in power systems; their function is to induce a small current—proportional to the current flowing through a high-current cable—for use in metering and relay protection. What is the function of a current transformer? To ensure the safe and economical operation of a power system, it is essential to monitor

Why Do Some Switchgear Have One CT While Others Have Three? Đọc thêm »

Main Structure of Our New Production Building Successfully Topped Out

2026-10-12 On October 11, 2026, the main structure of our new production building was successfully topped out, marking a major milestone in the project’s construction. This achievement lays a solid foundation for the remaining construction work and the building’s completion and commissioning. With the main structure now complete, the project will move on to the

Main Structure of Our New Production Building Successfully Topped Out Đọc thêm »

Strengthening Global Partnerships Advancing SF6-Free Solutions at Hannover Messe 2026

2026-04-24 From April 20 to 24, 2026, we proudly exhibited at Hannover Messe 2026 in Germany, marking our third consecutive year at this premier global industrial event. Throughout the exhibition, we had the pleasure of reconnecting with our long-standing partners, further deepening our cooperation and mutual trust. We also engaged in detailed and constructive discussions

Strengthening Global Partnerships Advancing SF6-Free Solutions at Hannover Messe 2026 Đọc thêm »

Necessity of Short-Circuit Making Capability for Earthing Switches in MV RMUs

2026-01-05 Functional Role of the Earthing Switch In medium-voltage ring main units (RMUs), the earthing switch (ES) is often regarded as a device intended solely for maintenance grounding. However, under several credible operating and fault conditions, the earthing switch may be required to make onto a live circuit and withstand the resulting short-circuit current. For

Necessity of Short-Circuit Making Capability for Earthing Switches in MV RMUs Đọc thêm »

Good News! Our 24kV and 38kV Permanent Magnetic Auto Reclosers Passed the Full Tests at XIHARI

2025-12-16 Recently, our company’s independently developed 24kV and 38kV permanent magnetic auto reclosers successfully completed all project tests at the Xi’an High Voltage Apparatus Research Institute (XIHARI). ◆ The 24kV/16kA permanent magnet drive recloser passed the T100 test according to IEC 62271-111.7.103, with the rated operating sequence being O-0.1s-CO-1s-CO-1s-CO-60s-CO, and passed all three tests successfully. ◆ The 38kV/16kA permanent

Good News! Our 24kV and 38kV Permanent Magnetic Auto Reclosers Passed the Full Tests at XIHARI Đọc thêm »

Công ty chúng tôi đã phát triển thành công RMU ngoài trời tiết kiệm chi phí

2024-05-30 Đáp ứng yêu cầu của khách hàng nước ngoài mới, công ty chúng tôi đã phát triển thành công một đơn vị vòng chính tiết kiệm có thể sử dụng cả ngoài trời và trong nhà. Sau khi thử nghiệm, các tính chất cơ học và các chỉ số điện khác nhau đều đáp ứng được yêu cầu của khách hàng. Khách hàng của chúng tôi rất hài lòng với tốc độ phát triển và hiệu suất tổng thể của chúng tôi!

Công ty chúng tôi đã phát triển thành công RMU ngoài trời tiết kiệm chi phí Đọc thêm »

Tiết lộ độc quyền quá khứ và hiện tại của điện áp cực cao của Trung Quốc (Nửa đầu)

2024-05-20 Trong hoàn cảnh “không có tiêu chuẩn, không có kinh nghiệm và không có thiết bị” trên thế giới, UHV của Trung Quốc đã chuyển đổi thành công từ “bắt đầu từ con số không” thành “một quốc gia lớn có thiết bị quan trọng”, từ “Do Trung Quốc sáng tạo” thành “Do Trung Quốc dẫn đầu”, từ “Thiết bị tại Trung Quốc” thành “Thế giới thiết bị”. Có thể nói rằng việc xây dựng UHV

Tiết lộ độc quyền quá khứ và hiện tại của điện áp cực cao của Trung Quốc (Nửa đầu) Đọc thêm »

Tiết lộ độc quyền quá khứ và hiện tại của điện áp cực cao của Trung Quốc (Nửa sau)

2024-05-29 Chinh phục “đỉnh Everest” của điện, UHV là “bắt đầu từ con số không” tại Trung Quốc. Từ năm 2004, Tổng công ty lưới điện quốc gia Trung Quốc đã tổ chức hàng chục viện nghiên cứu khoa học và trường đại học, hơn 200 công ty sản xuất thiết bị, hơn 500 đơn vị xây dựng và hàng trăm nghìn người tham gia nghiên cứu cơ bản, công nghệ UHV

Tiết lộ độc quyền quá khứ và hiện tại của điện áp cực cao của Trung Quốc (Nửa sau) Đọc thêm »