Leak Prevention & Detection of MV Gas-Insulated RMU Switchgear

2026-10-12 For SF6-insulated Ring Main Units (RMU) or GIS, the leakage rate requirement depends on whether the gas compartment is classified as a closed pressure system or a sealed pressure system under IEC standards. 1. IEC 62271-1 (General HV Switchgear Standard) IEC 62271-1 defines: Gas system type Maximum SF6 leakage rate Closed pressure system ≤ 0.5% per year […]

Leak Prevention & Detection of MV Gas-Insulated RMU Switchgear مزید پڑھ "

Why Do Some Switchgear Have One CT While Others Have Three?

2026-10-12 Current transformers are widely used in power systems; their function is to induce a small current—proportional to the current flowing through a high-current cable—for use in metering and relay protection. What is the function of a current transformer? To ensure the safe and economical operation of a power system, it is essential to monitor

Why Do Some Switchgear Have One CT While Others Have Three? مزید پڑھ "

Main Structure of Our New Production Building Successfully Topped Out

2026-10-12 On October 11, 2026, the main structure of our new production building was successfully topped out, marking a major milestone in the project’s construction. This achievement lays a solid foundation for the remaining construction work and the building’s completion and commissioning. With the main structure now complete, the project will move on to the

Main Structure of Our New Production Building Successfully Topped Out مزید پڑھ "

Strengthening Global Partnerships Advancing SF6-Free Solutions at Hannover Messe 2026

2026-04-24 From April 20 to 24, 2026, we proudly exhibited at Hannover Messe 2026 in Germany, marking our third consecutive year at this premier global industrial event. Throughout the exhibition, we had the pleasure of reconnecting with our long-standing partners, further deepening our cooperation and mutual trust. We also engaged in detailed and constructive discussions

Strengthening Global Partnerships Advancing SF6-Free Solutions at Hannover Messe 2026 مزید پڑھ "

Necessity of Short-Circuit Making Capability for Earthing Switches in MV RMUs

2026-01-05 Functional Role of the Earthing Switch In medium-voltage ring main units (RMUs), the earthing switch (ES) is often regarded as a device intended solely for maintenance grounding. However, under several credible operating and fault conditions, the earthing switch may be required to make onto a live circuit and withstand the resulting short-circuit current. For

Necessity of Short-Circuit Making Capability for Earthing Switches in MV RMUs مزید پڑھ "

Good News! Our 24kV and 38kV Permanent Magnetic Auto Reclosers Passed the Full Tests at XIHARI

2025-12-16 Recently, our company’s independently developed 24kV and 38kV permanent magnetic auto reclosers successfully completed all project tests at the Xi’an High Voltage Apparatus Research Institute (XIHARI). ◆ The 24kV/16kA permanent magnet drive recloser passed the T100 test according to IEC 62271-111.7.103, with the rated operating sequence being O-0.1s-CO-1s-CO-1s-CO-60s-CO, and passed all three tests successfully. ◆ The 38kV/16kA permanent

Good News! Our 24kV and 38kV Permanent Magnetic Auto Reclosers Passed the Full Tests at XIHARI مزید پڑھ "

ہماری کمپنی نے لاگت سے موثر آؤٹ ڈور RMU کو کامیابی کے ساتھ تیار کیا۔

2024-05-30 نئے غیر ملکی گاہکوں کی ضروریات کے جواب میں، ہماری کمپنی نے کامیابی کے ساتھ ایک اقتصادی رِنگ مین یونٹ تیار کیا ہے جسے باہر اور گھر کے اندر استعمال کیا جا سکتا ہے۔ جانچ کے بعد، مکینیکل خصوصیات اور مختلف برقی اشارے سبھی نے گاہک کی ضروریات کو پورا کیا۔ ہمارے صارفین ہماری ترقی کی رفتار اور مجموعی کارکردگی سے بہت مطمئن ہیں! یہ

ہماری کمپنی نے لاگت سے موثر آؤٹ ڈور RMU کو کامیابی کے ساتھ تیار کیا۔ مزید پڑھ "

چین کے الٹرا ہائی وولٹیج کے ماضی اور حال کو خصوصی طور پر ظاہر کرتا ہے (پہلا نصف)

2024-05-20 دنیا میں "کوئی معیار، کوئی تجربہ اور کوئی سازوسامان نہیں" کے حالات میں، چین کا UHV کامیابی سے "شروع سے شروع" سے "اہم سازوسامان کے ساتھ ایک بڑے ملک" میں، "چین میں تخلیق کردہ" سے "چین کی قیادت میں"، "چین میں سازوسامان" سے "دنیا میں سازوسامان" میں تبدیل ہو گیا ہے۔ یہ کہا جا سکتا ہے کہ UHV کی تعمیر

چین کے الٹرا ہائی وولٹیج کے ماضی اور حال کو خصوصی طور پر ظاہر کرتا ہے (پہلا نصف) مزید پڑھ "

چین کے الٹرا ہائی وولٹیج (دوسرے نصف) کے ماضی اور حال کو خصوصی طور پر ظاہر کرتا ہے۔

2024-05-29 بجلی کے "ماؤنٹ ایورسٹ" کو فتح کرنا، UHV چین میں "شروع سے آغاز" ہے۔ 2004 سے، اسٹیٹ گرڈ کارپوریشن آف چائنا نے درجنوں سائنسی تحقیقی اداروں اور یونیورسٹیوں، 200 سے زیادہ آلات بنانے والی کمپنیوں، 500 سے زیادہ تعمیراتی یونٹس، اور لاکھوں لوگوں کو UHV بنیادی تحقیق، ٹیکنالوجی میں حصہ لینے کے لیے منظم کیا ہے۔

چین کے الٹرا ہائی وولٹیج (دوسرے نصف) کے ماضی اور حال کو خصوصی طور پر ظاہر کرتا ہے۔ مزید پڑھ "